<p lang="en-US" align="justify" style="margin-bottom: 0cm; line-height: 100%;"><font face="Verdana, sans-serif"><font size="2" style="font-size: 10pt;">Since our establishment in year 1996, we have been committed towards manufacturing, exporting and supplying <strong>CO2 Transmitter </strong>that is known for its high efficiency and optimum throughput. At our premises, the offered transmitter is manufactured with the use of excellent quality components and the contemporary technology in compliance with the international quality standards. Used for measurement of temperature and concentration of CO2 gas, the provided transmitter is applicable in various industrial applications. Moreover, clients can avail this <strong>CO2 Transmitter</strong> in various specifications at most economic rates from us. </font></font></p><p lang="en-US" align="justify" style="margin-bottom: 0cm; font-weight: normal; line-height: 100%;"><font face="Verdana, sans-serif"><font size="2" style="font-size: 10pt;"> </font></font></p><p lang="en-US" align="justify" style="margin-bottom: 0cm; line-height: 100%;"><font face="Verdana, sans-serif"><font size="2" style="font-size: 10pt;"><strong>Features: </strong></font></font></p><div align="justify"> <ul> <li> <p><font size="2" face="verdana,arial,helvetica,sans-serif" style="font-size: 10pt;">Patented, Absorption Infrared Gas sensing engine provides high accuracy in a compact low cost package. </font></p> </li> <li> <p><font size="2" face="verdana,arial,helvetica,sans-serif" style="font-size: 10pt;">Patented ABC Logicâââ¬Å¾Ã¢ self-calibration system eliminates the need for manual calibration in most applications. </font></p> </li> <li> <p><font size="2" face="verdana,arial,helvetica,sans-serif" style="font-size: 10pt;">Lifetime CO2 calibration guarantee when using ABC Logicâââ¬Å¾Ã¢. âââ¬Ã¢ Mounting plate with two-piece terminal blocks provide quick, easy wiring. </font></p> </li> <li> <p><font size="2" face="verdana,arial,helvetica,sans-serif" style="font-size: 10pt;">Gas permeable, water resistant CO2 diffusion filter prevents particulate and water contamination of the sensor. </font></p> </li> <li> <p><font size="2" face="verdana,arial,helvetica,sans-serif" style="font-size: 10pt;">Locking screw secures cover and sensor to the mounting bracket for tamper resistance. </font></p> </li> <li> <p><font size="2" face="verdana,arial,helvetica,sans-serif" style="font-size: 10pt;">Sensors are shipped factory calibrated. </font></p> </li> <li> <p><font size="2" face="verdana,arial,helvetica,sans-serif" style="font-size: 10pt;">Modern enclosure </font></p> </li> <li> <p><font size="2" face="verdana,arial,helvetica,sans-serif" style="font-size: 10pt;">Low-cost </font></p> </li> <li> <p><font size="2" face="verdana,arial,helvetica,sans-serif" style="font-size: 10pt;">Reliable (20 years of low-cost infrared sensor manufacturing) </font></p> </li> <li> <p><font size="2" face="verdana,arial,helvetica,sans-serif" style="font-size: 10pt;">UIP software compatible for customizations </font></p> </li> <li> <p><font size="2" face="verdana,arial,helvetica,sans-serif" style="font-size: 10pt;">CE, RoHS, REACH and WEEE compliant </font></p> </li> </ul> </div><p lang="en-US" align="justify" style="margin-bottom: 0cm; font-weight: normal; line-height: 100%;"><font face="Verdana, sans-serif"><font size="2" style="font-size: 10pt;"> </font></font></p><p lang="en-US" align="justify" style="margin-bottom: 0cm; line-height: 100%;"><font face="Verdana, sans-serif"><font size="2" style="font-size: 10pt;"><strong>Specifications: </strong></font></font></p><p lang="en-US" align="justify" style="margin-bottom: 0cm; font-weight: normal; line-height: 100%;"><font face="Verdana, sans-serif"><font size="2" style="font-size: 10pt;">1. CO2 Measurement Range: 0 to 2000 ppm </font></font></p><p lang="en-US" align="justify" style="margin-bottom: 0cm; font-weight: normal; line-height: 100%;"><font face="Verdana, sans-serif"><font size="2" style="font-size: 10pt;">2. CO2 Accuracy 400-1250 ppm Ãâñ 40 ppm + 3% of reading </font></font></p><p lang="en-US" align="justify" style="margin-bottom: 0cm; font-weight: normal; line-height: 100%;"><font face="Verdana, sans-serif"><font size="2" style="font-size: 10pt;">1250-2000 ppm Ãâñ5% of reading + 30ppm *, ** </font></font></p><p lang="en-US" align="justify" style="margin-bottom: 0cm; font-weight: normal; line-height: 100%;"><font face="Verdana, sans-serif"><font size="2" style="font-size: 10pt;">*Tolerance based on span gas of Ãâñ2% </font></font></p><p lang="en-US" align="justify" style="margin-bottom: 0cm; font-weight: normal; line-height: 100%;"><font face="Verdana, sans-serif"><font size="2" style="font-size: 10pt;">** ABC Logic not deactivated </font></font></p><p lang="en-US" align="justify" style="margin-bottom: 0cm; font-weight: normal; line-height: 100%;"><font face="Verdana, sans-serif"><font size="2" style="font-size: 10pt;">3. Sensing Method </font></font></p><p lang="en-US" align="justify" style="margin-bottom: 0cm; font-weight: normal; line-height: 100%;"><font face="Verdana, sans-serif"><font size="2" style="font-size: 10pt;">Non-dispersive infrared (NDIR) absorption </font></font></p><p lang="en-US" align="justify" style="margin-bottom: 0cm; font-weight: normal; line-height: 100%;"><font face="Verdana, sans-serif"><font size="2" style="font-size: 10pt;">Gold-plated optics </font></font></p><p lang="en-US" align="justify" style="margin-bottom: 0cm; font-weight: normal; line-height: 100%;"><font face="Verdana, sans-serif"><font size="2" style="font-size: 10pt;">Patented ABC Logic self calibration algorithm </font></font></p><p lang="en-US" align="justify" style="margin-bottom: 0cm; font-weight: normal; line-height: 100%;"><font face="Verdana, sans-serif"><font size="2" style="font-size: 10pt;">4. Power Supply Requirements </font></font></p><p lang="en-US" align="justify" style="margin-bottom: 0cm; font-weight: normal; line-height: 100%;"><font face="Verdana, sans-serif"><font size="2" style="font-size: 10pt;">18-30 VAC RMS, 50/60 Hz, or 18 to 42 VDC, </font></font></p><p lang="en-US" align="justify" style="margin-bottom: 0cm; font-weight: normal; line-height: 100%;"><font face="Verdana, sans-serif"><font size="2" style="font-size: 10pt;">polarity protected </font></font></p><p lang="en-US" align="justify" style="margin-bottom: 0cm; font-weight: normal; line-height: 100%;"><font face="Verdana, sans-serif"><font size="2" style="font-size: 10pt;">*AHRAE âââ‰â¬Â regulation 62 states maximum indoor CO2 level of 1000 ppm </font></font></p><p lang="en-US" align="justify" style="margin-bottom: 0cm; font-weight: normal; line-height: 100%;"><font face="Verdana, sans-serif"><font size="2" style="font-size: 10pt;">5. Signal Update: Every 5 seconds </font></font></p><p lang="en-US" align="justify" style="margin-bottom: 0cm; font-weight: normal; line-height: 100%;"><font face="Verdana, sans-serif"><font size="2" style="font-size: 10pt;">6. CO2 Warm-up Time </font></font></p><p lang="en-US" align="justify" style="margin-bottom: 0cm; font-weight: normal; line-height: 100%;"><font face="Verdana, sans-serif"><font size="2" style="font-size: 10pt;">< 2 minutes (operational) </font></font></p><p lang="en-US" align="justify" style="margin-bottom: 0cm; font-weight: normal; line-height: 100%;"><font face="Verdana, sans-serif"><font size="2" style="font-size: 10pt;">10 minutes (maximum accuracy) </font></font></p><p lang="en-US" align="justify" style="margin-bottom: 0cm; font-weight: normal; line-height: 100%;"><font face="Verdana, sans-serif"><font size="2" style="font-size: 10pt;">7. Operating Conditions </font></font></p><p lang="en-US" align="justify" style="margin-bottom: 0cm; font-weight: normal; line-height: 100%;"><font face="Verdana, sans-serif"><font size="2" style="font-size: 10pt;">32ÃâðF to 122ÃâðF (0ÃâðC to 50ÃâðC) </font></font></p><p lang="en-US" align="justify" style="margin-bottom: 0cm; font-weight: normal; line-height: 100%;"><font face="Verdana, sans-serif"><font size="2" style="font-size: 10pt;">0 to 95% RH, non-condensing </font></font></p><p lang="en-US" align="justify" style="margin-bottom: 0cm; font-weight: normal; line-height: 100%;"><font face="Verdana, sans-serif"><font size="2" style="font-size: 10pt;">8. Storage Conditions </font></font></p><p lang="en-US" align="justify" style="margin-bottom: 0cm; font-weight: normal; line-height: 100%;"><font face="Verdana, sans-serif"><font size="2" style="font-size: 10pt;">-40ÃâðF to 158ÃâðF (-40ÃâðC to 70ÃâðC) </font></font></p><p lang="en-US" align="justify" style="margin-bottom: 0cm; font-weight: normal; line-height: 100%;"><font face="Verdana, sans-serif"><font size="2" style="font-size: 10pt;">9. Flammability Classification: UL94 5VA </font></font></p><p lang="en-US" align="justify" style="margin-bottom: 0cm; font-weight: normal; line-height: 100%;"><font face="Verdana, sans-serif"><font size="2" style="font-size: 10pt;">10. Output: </font></font></p><p lang="en-US" align="justify" style="margin-bottom: 0cm; font-weight: normal; line-height: 100%;"><font face="Verdana, sans-serif"><font size="2" style="font-size: 10pt;">0 to 5 V, or 0 to 10 V jumper selectable (100 Îé output </font></font></p><p lang="en-US" align="justify" style="margin-bottom: 0cm; font-weight: normal; line-height: 100%;"><font face="Verdana, sans-serif"><font size="2" style="font-size: 10pt;">impedance) </font></font></p><p lang="en-US" align="justify" style="margin-bottom: 0cm; font-weight: normal; line-height: 100%;"><font face="Verdana, sans-serif"><font size="2" style="font-size: 10pt;">Or 4 to 20 mA (RL maximum 500 Îé) </font></font></p><p lang="en-US" align="justify" style="margin-bottom: 0cm; font-weight: normal; line-height: 100%;"><font face="Verdana, sans-serif"><font size="2" style="font-size: 10pt;">Voltage and current outputs are not available </font></font></p><p lang="en-US" align="justify" style="margin-bottom: 0cm; font-weight: normal; line-height: 100%;"><font face="Verdana, sans-serif"><font size="2" style="font-size: 10pt;">simultaneously </font></font></p><p lang="en-US" align="justify" style="margin-bottom: 0cm; font-weight: normal; line-height: 100%;"><font face="Verdana, sans-serif"><font size="2" style="font-size: 10pt;">Digital to analog error Ãâñ1% </font></font></p><p lang="en-US" align="justify" style="margin-bottom: 0cm; font-weight: normal; line-height: 100%;"><font face="Verdana, sans-serif"><font size="2" style="font-size: 10pt;"> </font></font></p><p lang="en-US" align="justify" style="margin-bottom: 0cm; line-height: 100%;"><font face="Verdana, sans-serif"><font size="2" style="font-size: 10pt;"><strong>Ordering Information: </strong></font></font></p><p lang="en-US" align="justify" style="margin-bottom: 0cm; line-height: 100%;"><font face="Verdana, sans-serif"><font size="2" style="font-size: 10pt;"><strong>Examples: </strong></font></font></p><p lang="en-US" align="justify" style="margin-bottom: 0cm; font-weight: normal; line-height: 100%;"><font face="Verdana, sans-serif"><font size="2" style="font-size: 10pt;">T5100 - 10 V output = 10 V </font></font></p><p lang="en-US" align="justify" style="margin-bottom: 0cm; font-weight: normal; line-height: 100%;"><font face="Verdana, sans-serif"><font size="2" style="font-size: 10pt;">T5100-E-GN-5v Euro case size, no branding, 5v output </font></font></p><p lang="en-US" align="justify" style="margin-bottom: 0cm; font-weight: normal; line-height: 100%;"><font face="Verdana, sans-serif"><font size="2" style="font-size: 10pt;">T5100-I output = 4-20 mA </font></font></p>