TradeIndia
  • Sell
  • Buy
  • Sell
in Bulk
voice search
X Ray Control Panel (300 Ma 100 Kvp)

X Ray Control Panel (300 Ma 100 Kvp)

Get LatestPrice
Get Best Deals

X-Ray System:Medilux 300 generator is designed to fulfill the requirements of all Radiography, Fluoroscope, Spot Filming and Special procedures with m...View Product Details

Product Overview

Key Features

X-Ray System:Medilux 300 generator is designed to fulfill the requirements of all Radiography, Fluoroscope, Spot Filming and Special procedures with manual or motorized table. The generator is suitable for use with image intensifier TV systems.Controls: Line switches: ON & OFF push button switches control line contractor. Voltage compensator switch: A 15 position switch for voltage compensation in the range 180 to 250volts. Voltmeter indicator at red bond indicates compensated voltage at 230 volts. Major KVp Control: A 12 position switch for coarse selection of KVp. Minor KVp Control: A 12 position selector switch for fine selection of KVp enable selection of 1 KVp per step in range of 40 to 100 KVp. Fluoroscopy KVp Selector: A 12 position independent switch permits selection of fluoroscope KVp values from 45 to 100 KVp in step of 5KVp. mA technique control: Rotary switch permits one of the following mA selections 50mA, 100mA on small focus and 200mA, 300mA on large focus. Tube selector: A toggle switch with 'F' & 'R' option selects under couch or over couch X-Ray tube. Radiographic Timer: A 24-position switch permits exposure time selections from 0.02 to 10 seconds. Fluoroscopic Timer: It permits operator to limit fluoroscopic examination to any integrated time upto 5 minutes. Approx. 20 seconds before termination of preselected time: timer will initiate a buzzer. Fluaro mA Selector: Continuously variable fluoro mA knob permits selection of mA from 0-3 mA. Fluoroxcopy exposure switch: Fluoro test. Indicators: Digital read out for KVp & mAS Radiography/Spot Film exposure parameters. Selected Facal Spot is indicated on display penal. X-Ray LED glows during exposure period. MA meter: Radiographic actual mA value is indicated on 0 - 350 mA analogue scale and actual fluoro mA value is indicated on 0-10 mA scale. Tube overload LED glows in case selected factors are in excess of X-Ray tube exposure rating. Power Line Requirement:Power demand at rated output: Single phase, 50HZ, and 30 KVA 3 phase to single pahse transformer is recommended, maximum allowable line resistance in 415 line is 0.5 Ohms.Compatible with:Motorized or Monual Table, Spot Film Device and IITV.

Company Details

MEDILUX SYSTEMS, Established in 1996 at Delhi in Delhi, is a leading service provider of X-Ray Machine in India. MEDILUX SYSTEMS is one of Trade India's verified and trusted names for listed services. With extensive experience in the field of X-Ray Machine, MEDILUX SYSTEMS has made a reputed name for itself in the market with satisfactory 100-mA X-ray machine Control Panel, 60 /100 mA on Counter Balanced Mobile Stand, Dental X Ray System, etc.
Focusing on a customer-centric approach, MEDILUX SYSTEMS has a pan-India presence and caters to a huge consumer base throughout the country. Get X-Ray Machine from MEDILUX SYSTEMS at Trade India quality-assured services.

Business Type

Exporter, Manufacturer, Service Provider, Distributor, Supplier, Trading Company

Employee Count

30

Establishment

1996

Working Days

Monday To Sunday

Certification

APPROVED BY BHAVA ATOMIC RESEARCH CENTER/AUTOMIC ENERGY REGULATORY BOARD OF INDIA

Seller Details

M

MEDILUX SYSTEMS

Proprietor

Mr. Raman Singla

Address

E-1, 11/1, Sector-15, Rohini, Delhi, Delhi, 110085, India

x ray machine parts in Delhi

Report incorrect details