• Sell
  • Buy
  • Sell
in Bulk
voice search
On-line Analyzers

Murrah On-line Analyzers

Get LatestPrice
Get Best Deals

MICROMAC COD   On-line analyzers for COD monitoring in water and wastewater   Three versions of COD on-line analyzers ar...View Product Details

Product Overview

Key Features

MICROMAC COD   On-line analyzers for COD monitoring in water and wastewater   Three versions of COD on-line analyzers are available: dichromate method permanganate index method UV direct reading method. The dichromate method follows the international standard where in the sample, after filtration, Potassium Dichromate, Mercury (II) sulfate and Sulfuric acid with a proper catalyst are added; Mercury (II) sulfate concentration is adjusted to mask the expected Chloride amount. The sample is then heated at 170 for 20 minutes or at 150 up to 2 hours (digestion time and digestion temperature can be adjusted depending on the matrix to digest completely all the substances that give a contribute to COD). After digestion the sample is cooled and the absorbance measured at 592 nm is proportional to a COD concentration. The permanganate index is defined as the quantity of oxygen, expressed as mg/l, equivalent to the consumed permanganate when a water sample is treated with as solution of potassium permanganate in acid environment and at a temperature of 100C for 10 minutes. The sample is mixed with diluted sulphuric acid, it is then heated at about 100C, when the first addition of KMnO4 is performed: this first addition may be followed by others, depending on the measuring range. The digestion time in the standard configuration is set to 10 minutes but it can be selected depending on the matrix. After digestion the sample is cooled and the decrease of the absorbance measured at 525 nm corresponds to the permanganate consumed by the organic substance. The UV direct reading method is a more simple method where the COD is correlated to the direct light absorption of the water sample measured at 254 nm. 4. MICROMAC TOC   On-line analyzer for TOC monitoring in water and wastewater MICROMAC TOC is a microprocessor controlled On Line analyzer specifically designed for automatic TOC monitoring on several type of water matrices, including sea water. The analyzer is based on the standard UV-persulphate method coupled with aNon Dispersive InfraRed (NDIR) detector. Robust and Reliable Designed for industrial and environmental on-line applications, Micromac C ensures the highest level of reliability in the electronics, mechanics and hydraulics components.Complete separation between electronics and hydraulics plus a simple and robust hydraulics allows long term and reliable operations.   Easy to install The analyzer is delivered after a long and successful series of factory tests. It is ready for installation, without any further adjustment; it is provided completed with a spare set for start up. To start monitoring activity, Customer needs only to connect sample line, waste line and power supply and to insert reagents and calibrant into the internal compartment. Automatic Calibration As soon as user selectable Calibration Time expires, the analyzer perform a calibration cycle, storing and checking the new calibrant O. D. If new O.D. exceeds the selected limits, an alarm contact is closed.   Sample dilution Water sample can be analyzed as it is or after automatic dilution. Automatic dilution can be factory adjusted for high range applications. Internal air carrier generation The analyzer includes as standard an internal air generator as carrier gas. Measuring interval User selectable; between two measurements the analyzer remains in stand by mode, without reagents consumption.      Features and benefits Fully automatic operation Long autonomy; low maintenance, low operating cost Low reagents consumption; short preparation time; low disposable costs Easy operation; plug in analyzer, no special training is required  Electronics and hydraulics completely separated  Serial interface for local o remote PC connection.

Company Details

Business Type

Exporter, Distributor, Supplier, Trading Company

Establishment

2010

Seller Details

T

Triple Three India Energy Solutions (P) Ltd.

Director

Mr. Shyam Singh

Address

E-5, Agarwal Metro Height, Unit 752 Netaji Subhash Place, Pitampura, Delhi, Delhi, 110034, India

Filters-Air, Gas, Liquid in Delhi

Report incorrect details

Related Products

Oil Cleaners (Filter)

Oil Cleaners (Filter)

ADVANCE INTERNATIONAL

New Delhi, Delhi

Filter For Generator Sets

Filter For Generator Sets

Chadha Industries (P) Ltd.

New Delhi, Delhi

Double - Decker Filter

Double - Decker Filter

AQUATHERM WATER TREATMENT PVT. LTD.

Kolkata, West Bengal

Industrial Softener

Industrial Softener

Sab Water Treat

Kolkata, West Bengal

Online Pulsejet Bag Filters

Online Pulsejet Bag Filters

Dustven Pvt. Ltd.

Bengaluru, Karnataka

Filter

Filter

SHAKO CO., LTD.

Taoyuan, Taoyuan

Easy To Install Low Cost Automatic Filters

Easy To Install Low Cost Automatic Filters

ABPS SOLUTION PVT LTD

Pune, Maharashtra